SURVIVABILITY REPORT

« Back to front page

Compartment RSTK2

Properties

Description:service tank aft
Purpose:HFO
Volume:8.6 m³
Vessel: S-CORVETTE_EQP

Location of the compartment in the vessel and the EBPs surrounding the compartment:

EBPs

The following EBPs are located in this compartment:

NameAdjacent compartmentOrientationAreaPlate thicknessPlate materialPlate massStiffener materialMass from stiffenersTotal EBP massCoG XCoG YCoG ZBallistic protection IDBallistic protection thickness
EBP.RAUX1.1 RAUX1 X52.12 m²8.0 mmA3,272.97 kgA1,674.25 kg4,947.22 kg34.20 m0.00 m3.61 mMST8.0 mm
EBP.RCOR3.7 RCOR3 Z2.40 m²6.0 mmA113.04 kgA170.97 kg284.01 kg33.60 m0.00 m5.60 mMST6.0 mm
EBP.RERAFT.38 RERAFT Y2.88 m²6.0 mmA135.65 kgA26.38 kg162.02 kg33.60 m-1.50 m4.40 mMST6.0 mm
EBP.RERAFT.39 RERAFT Y2.88 m²6.0 mmA135.65 kgA26.38 kg162.02 kg33.60 m1.50 m4.40 mMST6.0 mm
EBP.RERAFT.40 RERAFT Z3.60 m²6.0 mmA169.56 kgA280.95 kg450.51 kg33.60 m0.00 m3.20 mMST6.0 mm
EBP.RERAFT.37 RERAFT X7.20 m²8.0 mmA452.16 kgA226.83 kg678.99 kg33.00 m0.00 m4.40 mMST8.0 mm
EBP.ROFF1.5 ROFF1 Z0.60 m²6.0 mmA28.26 kgA42.74 kg71.00 kg33.60 m-1.25 m5.60 mMST6.0 mm
EBP.ROMESS.5 ROMESS Z0.60 m²6.0 mmA28.26 kgA42.74 kg71.00 kg33.60 m1.25 m5.60 mMST6.0 mm

More information about Materials and Structures.

Equipment

This compartment does not contain any equipment.

Detonation

Detonation does not take place in this compartment in any of the cases.

Damage

The probability that this compartment gets damaged is 2.29 %.

It's damaged in the following cases:

#NameProbabilityCauseWarhead
12 EXOCET-RAUX1 2.29 %Pressure, fragmentation EXOCET

© 2017 Surma Ltd