SURVIVABILITY REPORT

« Back to front page

Case EXOCET-RSTO4P

Description

No stability issues. Probability assigned to this case: 0.44 %

Warhead

Warhead: EXOCET
Explosive:COMPB
Explosive mass:43.0 kg
Casing mass:119.0 kg

Detonation location

Compartment: RSTO4.P
Coordinates:X = 45.00 m, Y = 3.33 m, Z = 4.42 m

Operational readiness

Operational Readiness Level after hit: ORL4
Floating position indicative level:F1
Floating position description:No stability issues
Heel:0.00 °
System level:S4
Critical systems remaining:51.6 %
Non-critical systems remaining:
Systems remaining (critical or not):51.6 %
Equipment remaining:85.7 %
Compartment damage level:C2
The share of compartment volume not damaged:87.3 %
Compartments remaining:93.9 %

Structural Damage

Fragment Damage

Pressure Damage


Pressure damaged compartments:6
Fragmentation damaged compartments:6
Flooded compartments:0
Total damaged compartments:6

List of damaged compartments

IDDescriptionDamage type
RSTO4.P Storage space reservationPressure, fragmentation
RAUX1 auxiliary room centerPressure, fragmentation
RPUMP1 pump roomPressure, fragmentation
RSTO4.S Storage space reservationPressure, fragmentation
RWS1 workshopPressure, fragmentation
RERFORE engine room forePressure, fragmentation

Equipment Damage

List of lost equipment

IDEquipment tableDescriptionCause
Prop Switchboard EL PropulsionSwitchboard for el propulsionpressure
GENSET 1 MACHINERYDiesel generatorpressure
GENSET 2 MACHINERYDiesel eneratorpressure
GENSET 3 MACHINERYDiesel generatorpressure

Damage to Routes

IDLost, cause
Gen1-swbkilled:frag/
Gen3-swbkilled:frag/

Damage to Systems

NameIDParent systemRedundancy groupsCritical?Lost, causeRepairable, cause
EL propulsion EL propulsion Propulsion Propulsion RG Yespressure
Gen1 Prop Gen1 Prop EL propulsion EL propulsion Gensets RG Yesfragments, pressure
Gen1 Gen1 Gen1 Prop SWB1 GEN1 supply SWB2 GEN1 supply Yespressure
Gen2 Prop Gen2 Prop EL propulsion EL propulsion Gensets RG Yespressure
Gen2 Gen2 Gen2 Prop SWB1 GEN2 supply SWB2 GEN2 supply Yespressure
Gen3 PROP Gen3 PROP EL propulsion EL propulsion Gensets RG Yesfragments, pressure
Gen3 Gen3 Gen3 PROP SWB1 GEN3 supply SWB2 GEN3 supply Yespressure
EL Supply1 EL Supply1Yespressure
SWB1 GEN1 supply SWB1 GEN1 supply EL Supply1 EL Supply1 GENS RG Yesfragments, pressure
SWB1 GEN2 supply SWB1 GEN2 supply EL Supply1 EL Supply1 GENS RG Yespressure
SWB1 GEN3 supply SWB1 GEN3 supply EL Supply1 EL Supply1 GENS RG Yespressure
EL Supply2 EL Supply2Yespressure
SWB2 GEN1 supply SWB2 GEN1 supply EL Supply2 EL Supply2 GENS RG Yespressure
SWB2 GEN2 supply SWB2 GEN2 supply EL Supply2 EL Supply2 GENS RG Yespressure
SWB2 GEN3 supply SWB2 GEN3 supply EL Supply2 EL Supply2 GENS RG Yespressure

Floating Position

No stability issues.

InitialAfter hit
Draught:4.00 m4.00 m
Trim:0.00 m0.00 m
Heel:0.00 °0.00 °
GM:4.72 m4.73 m

Floating position after hit:

GZ Curve

GZ curve after hit:

Longitudinal Strength Curves

Longitudinal strength curves after hit:

No longitudinal strength curve available for this case.

© 2017 Surma Ltd