SURVIVABILITY REPORT

« Back to front page

Case 155MMSHELL-RMSW2

Description

No stability issues. Probability assigned to this case: 1.01 %

Warhead

Warhead: 155MMSHELL
Explosive:TNT
Explosive mass:7.0 kg
Casing mass:36.4 kg

Detonation location

Compartment: RMSW2
Coordinates:X = 54.56 m, Y = 3.73 m, Z = 7.12 m

Operational readiness

Operational Readiness Level after hit: ORL4
Floating position indicative level:F1
Floating position description:No stability issues
Heel:0.00 °
System level:S4
Critical systems remaining:58.1 %
Non-critical systems remaining:
Systems remaining (critical or not):58.1 %
Equipment remaining:96.4 %
Compartment damage level:C2
The share of compartment volume not damaged:87.2 %
Compartments remaining:92.9 %

Structural Damage

Fragment Damage

Pressure Damage


Pressure damaged compartments:2
Fragmentation damaged compartments:7
Flooded compartments:0
Total damaged compartments:7

List of damaged compartments

IDDescriptionDamage type
RMSW2 main switchboard 1Pressure, fragmentation
REQ3 Equipment space 3, DK4Pressure, fragmentation
RWS1 workshopFragmentation
RACC2-1 petty officiers, PFragmentation
RCOR6 Fragmentation
RERFORE engine room foreFragmentation
RCIC CICFragmentation

Equipment Damage

List of lost equipment

IDEquipment tableDescriptionCause
Main Swithcboard 2 Electricityfragments, pressure

Damage to Routes

IDLost, cause
BRI-POD2killed:frag/
BRI-Waterjet controlkilled:frag/
CIC EL supplykilled:frag/
GEN2 to SWB1killed:frag/
GEN3 to SWB1killed:frag/
GEN1 to SWB2killed:frag/
GEN2 to SWB2killed:frag/
GEN3 to SWB2killed:frag/
BRI to ENG2killed:frag/

Damage to Systems

NameIDParent systemRedundancy groupsCritical?Lost, causeRepairable, cause
BRI-Pod2 BRI-Pod2 Pod2 Yesfragments
BRI-Waterjet BRI-Waterjet Water jet Yesfragments
Command and Control Command and ControlYesfragments
Pod2 Pod2 EL propulsion EL propulsion Pods RG Yesfragments
SWB1 GEN2 supply SWB1 GEN2 supply EL Supply1 EL Supply1 GENS RG Yesfragments
SWB1 GEN3 supply SWB1 GEN3 supply EL Supply1 EL Supply1 GENS RG Yesfragments
EL Supply2 EL Supply2Yesfragments
SWB2 GEN1 supply SWB2 GEN1 supply EL Supply2 EL Supply2 GENS RG Yesfragments
SWB2 GEN2 supply SWB2 GEN2 supply EL Supply2 EL Supply2 GENS RG Yesfragments
SWB2 GEN3 supply SWB2 GEN3 supply EL Supply2 EL Supply2 GENS RG Yesfragments
Eng2 Eng2Yesfragments
Main engine 2 Main engine 2 Water jet Water jet Engine RG Yesfragments
Water jet Water jet Propulsion Propulsion RG Yesfragments

Floating Position

No stability issues.

InitialAfter hit
Draught:4.00 m4.00 m
Trim:0.00 m0.00 m
Heel:0.00 °0.00 °
GM:4.72 m4.73 m

Floating position after hit:

GZ Curve

GZ curve after hit:

Longitudinal Strength Curves

Longitudinal strength curves after hit:

No longitudinal strength curve available for this case.

© 2017 Surma Ltd