SURVIVABILITY REPORT

« Back to front page

Case 155MMSHELL-RECR2

Description

No stability issues. Probability assigned to this case: 1.01 %

Warhead

Warhead: 155MMSHELL
Explosive:TNT
Explosive mass:7.0 kg
Casing mass:36.4 kg

Detonation location

Compartment: RECR2
Coordinates:X = 54.56 m, Y = -3.73 m, Z = 7.12 m

Operational readiness

Operational Readiness Level after hit: ORL2
Floating position indicative level:F1
Floating position description:No stability issues
Heel:0.00 °
System level:S2
Critical systems remaining:87.1 %
Non-critical systems remaining:
Systems remaining (critical or not):87.1 %
Equipment remaining:100.0 %
Compartment damage level:C2
The share of compartment volume not damaged:87.2 %
Compartments remaining:92.9 %

Structural Damage

Fragment Damage

Pressure Damage


Pressure damaged compartments:2
Fragmentation damaged compartments:7
Flooded compartments:0
Total damaged compartments:7

List of damaged compartments

IDDescriptionDamage type
RECR2 Engine control room 2Pressure, fragmentation
REQ4 Equipment space 4, DK4Pressure, fragmentation
RSTO3 StoreFragmentation
RACC2-2 petty officiers, SFragmentation
RCOR6 Fragmentation
RERFORE engine room foreFragmentation
RCIC CICFragmentation

Equipment Damage

No damage to equipment.

Damage to Routes

IDLost, cause
GEN2 to SWB1killed:frag/
GEN3 to SWB1killed:frag/
GEN1 to SWB2killed:frag/
GEN2 to SWB2killed:frag/

Damage to Systems

NameIDParent systemRedundancy groupsCritical?Lost, causeRepairable, cause
SWB1 GEN2 supply SWB1 GEN2 supply EL Supply1 EL Supply1 GENS RG Yesfragments
SWB1 GEN3 supply SWB1 GEN3 supply EL Supply1 EL Supply1 GENS RG Yesfragments
SWB2 GEN1 supply SWB2 GEN1 supply EL Supply2 EL Supply2 GENS RG Yesfragments
SWB2 GEN2 supply SWB2 GEN2 supply EL Supply2 EL Supply2 GENS RG Yesfragments

Floating Position

No stability issues.

InitialAfter hit
Draught:4.00 m4.00 m
Trim:0.00 m0.00 m
Heel:0.00 °0.00 °
GM:4.72 m4.73 m

Floating position after hit:

GZ Curve

GZ curve after hit:

Longitudinal Strength Curves

Longitudinal strength curves after hit:

No longitudinal strength curve available for this case.