SURVIVABILITY REPORT

« Back to front page

Compartment R.TD02C

Properties

Description:Rudder Room
Purpose:Deck Store
Volume:24.9 m³
Vessel: PATROLBOAT

Location of the compartment in the vessel and the EBPs surrounding the compartment:

EBPs

The following EBPs are located in this compartment:

NameAdjacent compartmentOrientationAreaPlate thicknessPlate materialPlate massStiffener materialMass from stiffenersTotal EBP massCoG XCoG YCoG ZBallistic protection IDBallistic protection thickness
SURMA.EBP.R.DB02C.5 R.DB02C Z11.51 m²5.0 mmA451.94 kgA308.77 kg760.71 kg2.71 m0.00 m2.40 mMST4.0 mm
SURMA.EBP.R.DB03C.1 R.DB03C X14.07 m²7.0 mmA773.42 kgA358.16 kg1,131.58 kg3.60 m0.00 m3.44 mMST4.0 mm
SURMA.EBP.R.TD01C.2 R.TD01C X13.63 m²7.0 mmA748.92 kgA358.00 kg1,106.92 kg1.80 m0.00 m3.44 mMST4.0 mm
SURMA.EBP.R.TD02C.5 OUTSIDE Z6.17 m²5.0 mmA242.05 kgA170.65 kg412.70 kg2.70 m1.71 m4.46 mMST4.0 mm
SURMA.EBP.R.TD02C.4 OUTSIDE Z6.17 m²5.0 mmA242.05 kgA170.65 kg412.70 kg2.70 m-1.71 m4.46 mMST4.0 mm
SURMA.EBP.R.TD02C.7 OUTSIDE Y3.63 m²6.3 mmA179.38 kgA152.92 kg332.30 kg2.70 m-3.36 m3.38 mMST4.0 mm
SURMA.EBP.R.TD02C.6 OUTSIDE Y3.63 m²6.3 mmA179.38 kgA147.41 kg326.79 kg2.70 m3.36 m3.38 mMST4.0 mm

More information about Materials and Structures.

Equipment

This compartment does not contain any equipment.

Detonation

Detonation does not take place in this compartment in any of the cases.

Damage

This compartment is not damaged in any of the cases.

© 2016 Surma Ltd