SURVIVABILITY REPORT

« Back to front page

Compartment R.DM05S

Properties

Description:Emergency Generator
Purpose:Apparat Space
Volume:24.9 m³
Vessel: PATROLBOAT

Location of the compartment in the vessel and the EBPs surrounding the compartment:

EBPs

The following EBPs are located in this compartment:

NameAdjacent compartmentOrientationAreaPlate thicknessPlate materialPlate massStiffener materialMass from stiffenersTotal EBP massCoG XCoG YCoG ZBallistic protection IDBallistic protection thickness
SURMA.EBP.R.DB06C.12 R.DB06C Z3.92 m²5.0 mmA153.82 kgA159.46 kg313.28 kg13.13 m-2.01 m4.48 mMST4.0 mm
SURMA.EBP.R.TD03S.9 R.TD03S Z5.50 m²5.0 mmA215.74 kgA225.68 kg441.42 kg14.70 m-2.18 m4.50 mMST4.0 mm
SURMA.EBP.R.DM01C.37 R.DM01C Y8.79 m²4.0 mmALMG498.46 kgALMG414.96 kg113.43 kg13.94 m-0.65 m5.87 mAL4.0 mm
SURMA.EBP.R.DM02S.2 R.DM02S X1.75 m²4.0 mmALMG419.62 kgALMG41.52 kg21.14 kg12.30 m-0.98 m5.85 mAL4.0 mm
SURMA.EBP.R.DM04S.10 R.DM04S Y1.65 m²4.0 mmALMG418.46 kgALMG41.46 kg19.92 kg12.60 m-2.60 m5.83 mAL4.0 mm
SURMA.EBP.R.DM04S.9 R.DM04S X2.83 m²4.0 mmALMG431.72 kg0.00 kg31.72 kg12.90 m-3.11 m5.76 mAL4.0 mm
SURMA.EBP.R.DM04S.2 R.DM04S X3.54 m²4.0 mmALMG439.66 kgALMG44.51 kg44.17 kg12.30 m-1.95 m5.84 mAL4.0 mm
SURMA.EBP.R.DM05S.8 OUTSIDE Z0.70 m²4.0 mmA22.04 kgALMG425.46 kg47.51 kg12.48 m-1.62 m7.20 mMST4.0 mm
SURMA.EBP.R.DM05S.11 R.D101C Z0.76 m²4.0 mmA23.88 kgALMG43.47 kg27.35 kg13.83 m-0.81 m7.20 mMST4.0 mm
SURMA.EBP.R.DM05S.9 R.D103S Z1.71 m²4.0 mmA53.69 kgALMG48.79 kg62.49 kg15.30 m-2.08 m7.20 mMST4.0 mm
SURMA.EBP.R.DM05S.10 R.D102S Z5.69 m²4.0 mmA178.74 kgALMG457.98 kg236.72 kg13.87 m-2.21 m7.20 mMST4.0 mm
SURMA.EBP.R.DM05S.3 R.DM06S X7.97 m²4.0 mmALMG489.22 kgALMG413.08 kg102.29 kg15.60 m-2.15 m5.84 mAL4.0 mm
SURMA.EBP.R.DM05S.4 OUTSIDE Y7.55 m²4.0 mmALMG484.57 kgALMG422.23 kg106.80 kg14.25 m-3.62 m5.81 mAL4.0 mm

More information about Materials and Structures.

Equipment

The following equipment is located in this compartment:

IDEquipment tableDescription
GEN-ER EQP*ELEMERGENCY GENERATOR

Detonation

Detonation does not take place in this compartment in any of the cases.

Damage

This compartment is not damaged in any of the cases.