SURVIVABILITY REPORT

« Back to front page

Compartment R.DB10C

Properties

Description:Machinery
Purpose:Apparat Space
Volume:12.5 m³
Vessel: PATROLBOAT

Location of the compartment in the vessel and the EBPs surrounding the compartment:

EBPs

The following EBPs are located in this compartment:

NameAdjacent compartmentOrientationAreaPlate thicknessPlate materialPlate massStiffener materialMass from stiffenersTotal EBP massCoG XCoG YCoG ZBallistic protection IDBallistic protection thickness
SURMA.EBP.R.DB09C.2 R.DB09C X7.59 m²7.0 mmA417.30 kgA194.07 kg611.37 kg25.80 m0.00 m1.23 mMST4.0 mm
SURMA.EBP.R.DB10C.2 R.DB11S X3.16 m²7.0 mmA173.78 kgA80.31 kg254.09 kg27.60 m-0.85 m1.24 mMST4.0 mm
SURMA.EBP.R.DB10C.3 R.DB11P X3.16 m²7.0 mmA173.78 kgA80.31 kg254.09 kg27.60 m0.85 m1.24 mMST4.0 mm
SURMA.EBP.R.DB10C.6 R.TD06S Z4.50 m²5.0 mmA176.78 kgA105.94 kg282.72 kg26.68 m-1.25 m2.07 mMST4.0 mm
SURMA.EBP.R.DB10C.7 R.TD06P Z4.50 m²5.0 mmA176.78 kgA105.94 kg282.72 kg26.68 m1.25 m2.07 mMST4.0 mm
SURMA.EBP.R.DB10C.4 OUTSIDE Y6.16 m²6.3 mmA304.70 kgA291.71 kg596.40 kg26.69 m1.41 m0.82 mMST4.0 mm
SURMA.EBP.R.DB10C.5 OUTSIDE Y6.16 m²6.3 mmA304.70 kgA291.71 kg596.40 kg26.69 m-1.41 m0.82 mMST4.0 mm

More information about Materials and Structures.

Equipment

This compartment does not contain any equipment.

Detonation

Detonation does not take place in this compartment in any of the cases.

Damage

This compartment is not damaged in any of the cases.

© 2016 Surma Ltd