SURVIVABILITY REPORT

« Back to front page

Case EXOCET-RD105P

Description

No stability issues. Probability assigned to this case: 0.67 %

Warhead

Warhead: EXOCET
Explosive:TNT
Explosive mass:43.0 kg
Casing mass:119.0 kg

Detonation location

Compartment: R.D105P
Coordinates:X = 18.77 m, Y = 2.83 m, Z = 8.51 m

Operational readiness

Operational Readiness Level after hit: ORL4
Floating position indicative level:F1
Floating position description:No stability issues
Heel:0.00 °
System level:S2
Critical systems remaining:86.1 %
Non-critical systems remaining:
Systems remaining (critical or not):86.1 %
Equipment remaining:98.1 %
Compartment damage level:C4
The share of compartment volume not damaged:69.0 %
Compartments remaining:77.0 %

Structural Damage

Fragment Damage

Pressure Damage


Pressure damaged compartments:14
Fragmentation damaged compartments:11
Flooded compartments:0
Total damaged compartments:14

List of damaged compartments

IDDescriptionDamage type
R.D105P MachineryPressure, fragmentation
R.D103P CabinPressure, fragmentation
R.D104P StoragePressure, fragmentation
R.D106P MachineryPressure, fragmentation
R.DM05P MessPressure, fragmentation
R.DM04P StoragePressure
R.D101C CorridorPressure, fragmentation
R.D107P RadioPressure, fragmentation
R.DM01C CorridorPressure
R.D102P StoragePressure, fragmentation
R.D106C BridgePressure, fragmentation
R.D103S CabinPressure, fragmentation
R.D104S CabinPressure, fragmentation
R.DM07S GalleyPressure

Equipment Damage

List of lost equipment

IDEquipment tableDescriptionCause
RAD EQP*CONRadiopressure

Damage to Routes

IDLost, cause
EL4_backupkilled:frag/
AAG2killed:frag/
AAG4killed:frag/
COM1killed:frag/
RAD RM EL supplykilled:frag/
RAD_CICkilled:frag/
MG_C2killed:frag/
Trans1killed:frag/
Trans2 _2killed:frag/
STEERING1killed:frag/
Streering2 backupkilled:frag/

Damage to Systems

NameIDParent systemRedundancy groupsCritical?Lost, causeRepairable, cause
AAG1 AAG1Yesfragments
AAG1 BRI control AAG1 BRI control AAG1 AAG1 Control RG Yesfragments
AAG1 CIC control AAG1 CIC control AAG1 AAG1 Control RG Yesfragments
COM COMYesfragments, pressure
RAD RAD COM Yesfragments, pressure

Floating Position

No stability issues.

InitialAfter hit
Draught:2.29 m2.29 m
Trim:0.27 m0.29 m
Heel:0.00 °0.00 °
GM:1.00 m1.00 m

Floating position after hit:

GZ Curve

GZ curve after hit:

Longitudinal Strength Curves

Longitudinal strength curves after hit:

© 2017 Surma Ltd